High-quality custom-made sintered wire mesh filter device
Describe:
JSYL series equipment can filter out solid particles in various water and low-viscosity liquids (such as machined coolants), reduce liquid turbidity, purify water quality, reduce system dirt, bacteria, algae, rust, etc., and keep materials clean. In order to meet the requirements of system operation and downstream processes for liquid cleanliness, it can also be used to protect downstream key equipment from particle blockage, abrasion or fouling, and improve the operating efficiency and life of key equipment.
Control mode:
Automatic control: timing and pressure difference, filter timer to set the filter time, the filter time is up, start to drain, the drain time is set by the drain timer. At the same time, the control system compares the filter pressure difference with the set pressure difference. When the filter pressure difference reaches the set value, the filter is cleaned and drained. The drain time is set by the drain timer, and the drain time is up. When it is time to stop cleaning, the filter is restored to its original state, ready for the next filtration process.
Manual control: Switch the automatic/manual selection on the operation panel to the manual position, and the filter layer is drained.
PRODUCT PARAMETER | |||
Specifications | Equipment parameters | Specifications | Equipment parameters |
Equipment model |
JSYL-JDX-SD-DN(25-800) |
Cleaning method | Equipment's own filter element backwash |
Shell selection | Carbon steel/stainless steel | Filter element form | Multi-layer woven mesh sintered |
Single machine flow |
2-900m3/h
|
Number of filter elements |
3-7 elements
|
Rated pressure |
1.6MPa/2.5MPa/4.0MPa |
Filtration accuracy | 10-2000 μm |
Applicable viscosity (cp) | 1-40cp | Applicable temperature (°C) | 0-95°C |
Operation mode | Manual mechanical operation | Filter element replacement | Large cover flange replacement filter element |
Backwashing components
|
304 stainless steel | Filter element design | Cover replacement |
Power unit | Compound reducer | Position proximity switch | Inductive |
Backflushing node | Seven-star node disk | Pressure gauge | Seismic pressure gauge |
Filter replacement cycle | Half a year/more than one year | Installation method | Horizontal |